The following bar codes will change scale parameters intended for a Dual Cable
environment. To place the scanner in Dual Cable mode, please refer to
page 25.
If the MS2xx0 is currently in a Dual Cable configuration, temporarily disconnect
the Scale to Host cable prior to configuring the scale.
The MS2xx0 does not need to be in scale service mode.
The Scale Save Data bar code must be scanned last to save the changed
configuration (see page 2).
Scale = 8217 Protocol
³ 9 9 6 0 5 0
Communication Port Settings:
9600 Baud
7 Data Bits
1 Stop Bit
Even Parity
Scale = 8213 Protocol
³ 9 9 6 0 5 1
Set the scale RS232 protocol to 8213.
Communication Port Settings:
9600 Baud
7 Data Bits
1 Stop Bit
Even Parity