Metrologic MS7600 Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Czytniki kodów kreskowych Metrologic MS7600. Metrologic MS7600 User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
METROLOGIC INSTRUMENTS, INC.
MS7600 Horizon™ Series
Installation and User’s Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC.MS7600 Horizon™ SeriesInstallation and User’s Guide

Strona 2

6MOUNTING THE MS7600 SERIESOPTION B: Free Hanging SupportFigure 3: Package Flow (right)Free Hanging Support Option (bottom)

Strona 3 - LOCATIONS

7Figure 4: OCIA, InterfaceINSTALLATION FOR OCIA INTERFACE1. Turn off the host system.2. Connect the MVC cable to the2nd jack down from the top ofthe

Strona 4 - TABLE OF CONTENTS

8Figure 5: Keyboard WedgeInterfacesINSTALLATION FOR KEYBOARD WEDGE INTERFACE1. Turn of the host system.2. Disconnect the keyboard from the host.3.

Strona 5 - INTRODUCTION

9Figure 6: Stand-Alone KeyboardInterfaceINSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE1. Turn of the host system.2. Disconnect the keyboard from th

Strona 6 - SCANNER AND ACCESSORIES

10Figure 7: USB, InterfaceINSTALLATION FOR USB INTERFACE1. Turn off the host system.2. Connect the PowerLink USB cable tothe 2nd jack down from the

Strona 7 - REPLACEMENT PARTS

11Figure 8: RS232 orLight Pen InterfaceINSTALLATION FOR RS232 OR LIGHT PEN INTERFACES1. Turn off the host system.2. Connect the PowerLink cable int

Strona 8 - BEFORE INSTALLING YOUR MS7600

12INSTALLATION FOR RS232 OR LIGHT PEN INTERFACESStep 8, page 11 continued.For RS232 Communication:Scan 1st ³999998Recall DefaultsScan 2nd ³415554Ena

Strona 9

13Figure 9: RS232/IBM, InterfaceINSTALLATION FOR IBM 46XX INTERFACE1. Turn off the host system.2. Connect the MVC cable to the1st jack down from the

Strona 10 - MOUNTING THE MS7600 SERIES

14INSTALLATION OF AN AUXILIARY SCANNER1. Turn off the host system.2. Connect the PowerLink RS232 AUX cable [ MLPN 54-54667A ] to the 3rd jackdown fr

Strona 11 - Figure 4: OCIA, Interface

15INSTALLATION OF AN AUXILIARY SCANNER Figure 10: Connector Orientation (Top)Auxiliary Scanner Setup (Bottom)MLPN 54-54667A

Strona 13 - Interface

16SCANNER PARTSFigure 11: Scanner PartsOutput Window (Laser Aperture)Red LED (Located Under Window)Amber LED (Located Under Window)SpeakerCable

Strona 14 - NSTALLATION FOR USB INTERFACE

17MAINTENANCESmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning.For the

Strona 15 - Figure 8: RS232 or

18SCANNER LABELSEach scanner has a label on the back of the unit. The label contains informationsuch as the model number, date of manufacture, serial

Strona 16 - Step 8, page 11 continued

19AUDIBLE INDICATORSWhen the MS7600 scanner is in operation, it provides audible feedback. Thesesounds indicate the status of the scanner. Eight set

Strona 17 - Load 46xx IBM Defaults

20 VISUAL INDICATORSThere is a red LED and amber LED onthe front of the MS7600. When the scanner ison, the flashing or constant illumination of theLE

Strona 18 - MLPN 00-02407A-1 & -2 ]

21FAILURE MODESFigure 15: LEDsFlashing Amber and One Razzberry ToneThis indicates the scanner has experienced alaser subsystem failure. Return the un

Strona 19 - 54-54667A

22CHANGING THE BEEPER TONE & VOLUMEChanging the Beeper ToneBeeper tones may be programmed directly or incrementally using the followingbar code.

Strona 20 - SCANNER PARTS

23POWER SAVE MODES AND IR DETECTIONThe MS7600 has five programmable power save modes. Refer to theMetroSelect Programming Guide for additional inform

Strona 21 - EAS DEACTIVATION ANTENNA

24POWER SAVE MODES AND IR DETECTIONFigure 16: IR Activation Area Perpendicular to Package FlowSpecifications subject to change without notice.

Strona 22 - SCANNER LABELS

25SCAN VOLUME SPECIFICATIONS (BASED ON 100% UPC BAR CODES)Figure 17: Scan Volume in Plane Perpendicular to FlowFigure 18: Scan Volume in Plane Paralle

Strona 23 - AUDIBLE INDICATORS

iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo

Strona 24 - VISUAL INDICATORS

26DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Figure 19: Depth of Field Perpendicular to FlowMinimum Bar Code Element

Strona 25 - FAILURE MODES

27TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Strona 26 - Next Volume

28TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanning a particularsymbology that is notenabledUPC/EAN, Code 39, interleaved2

Strona 27

29TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe bar code mayhave been printedincorrectlyCheck if it is a checkdigit/characte

Strona 28

30TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONEverythingworks exceptfor a couple ofcharactersThese characters maynot be suppor

Strona 29 - SCAN VOLUME SPECIFICATIONS

31TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe host isreceiving data butthe data does notlook correct.The scanner and hostm

Strona 30 - ASED ON 100% UPC BAR CODES)

32DESIGN SPECIFICATIONSMS7600 SERIES DESIGN SPECIFICATIONSOPERATIONALLight Source: VLD 650 ± 10 nmLaser Power: 1.1 mW maximumDepth of Field:0 mm to 20

Strona 31 - TROUBLESHOOTING GUIDE

33DESIGN SPECIFICATIONS (CONTINUED)MS7600 SERIES DESIGN SPECIFICATIONSELECTRICALInput Voltage: 5.2VDC ± 0.25VPower: 2.6 WOperating Current: 500 mALas

Strona 32

34RS232 DEMONSTRATION PROGRAMIf an RS232 scanner is not communicating with your IBM compatible PC, keyin the following BASIC program to test that the

Strona 33

35APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number and factorydefault communications protocol.SCANNERVERSIONIDEN

Strona 34

iiiTABLE OF CONTENTSIntroduction...1Scanner an

Strona 35 - * Use MetroSet

36DEFAULT SETTINGSMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the factory

Strona 36 - DESIGN SPECIFICATIONS

37DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBNCR S=Poll Light Pen Source=Beeper Tone Normal==== = =Beep/Transmit S

Strona 37 - NVIRONMENTAL

38DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBConvert UPC-A toEAN-13== == =Transmit Lead Zero on UPC-E===== =Conve

Strona 38 - RS232 DEMONSTRATION PROGRAM

39DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBCarriage Return*===Line Feed - disabled bydefault in KBW*===Tab Prefi

Strona 39 - APPLICATIONS AND PROTOCOLS

40DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBCoupon Code 128==as code39===Programmable Code Lengths 7 avail.= ====

Strona 40 - DEFAULT SETTINGS

41DEFAULT SETTINGS (CONTINUED)Default settings for “Aux” interfaceThe slave scanner and the MS7600 always communicate via RS232. Data isrelayed to th

Strona 41 - DEFAULT SETTINGS (CONTINUED)

42SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsThe MS7600 scanner interfaces terminate to 10-pin modular jacks located onthe back of the un

Strona 42

43SCANNER AND CABLE TERMINATIONS (CONTINUED)3Figure 21: Scanner Interface PortsMS762x-37Keyboard Wedge,Stand-Keyboard or USBMS762x-37RS-232 or Light P

Strona 43

44SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector Configurations (Host End)PowerLink Cable MLPN 54-54xxx*Pin Function1 Shield Ground2 RS-232

Strona 44

45SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connector onone end

Strona 45

1INTRODUCTIONThe MS7600 Horizon™ series is Metrologic’s next generation in-counter laser barcode scanner. This compact, hands-free scanner is designe

Strona 46 - Scanner Pinout Connections

46LIMITED WARRANTYThe MS7600 Series scanners are manufactured by Metrologic at its Blackwood, NewJersey, U.S.A. facility. The MS7600 Series scanners h

Strona 47 - RS-232 or Light Pen

47NOTICESNoticeThis equipment has been tested and found to comply with limits for a Class A digital device, pursuant toPart 15 of the FCC Rules. Thes

Strona 48

48NOTICES (CONTINUED)European StandardWarningThis is a class A product. In a domestic environment this product may cause radiointerference in which c

Strona 49 - PowerLink Cable Adapter Cable

49PATENTS“Patent InformationThis METROLOGIC product may be covered by one or more of the following U.S. Patents:U.S. Patent No.;4,960,985; 5,081,342;

Strona 50 - LIMITED WARRANTY

50INDEX AAccessories ...2Adapter...45Audible...19Auto

Strona 51

51INDEXTTermination...32Transformers ...33Troubleshooting27, 28, 29, 30, 31UUSB ...

Strona 52 - NOTICES (CONTINUED)

February 2002Printed in the USA 00-02870

Strona 53

2SCANNER AND ACCESSORIESBASIC KITPart # DescriptionMS7600 Horizon™ Series Scanner00-02407A-1&00-02407A-2MetroSelect® Programming Guide Two Book Se

Strona 54 - INDEX

3SCANNER AND ACCESSORIES (CONTINUED)OPTIONAL ACCESSORIESPart # DescriptionAC to DC Power Transformer - Regulated 5.2V@650 mA output45-45593 120V Unite

Strona 55

4BEFORE INSTALLING YOUR MS7600When mounting the MS7600 or replacingthe Top Plate:DO NOT Turnthe unit upside down.DO NOT Presson the window.Lift the To

Strona 56 - 00-02870

5MOUNTING THE MS7600 SERIESThere are two options for mounting your MS7600. Option “A” uses a shelf tosupport the unit and Option B lets the unit hang

Komentarze do niniejszej Instrukcji

Brak uwag