MOUNTING SPECIFICATIONS
IS4910-01 Dimensions
The IS4910-01 model has two blind holes located on the bottom of the engine for
use with self-tapping screws. This model includes two additional clearance holes
located on tabs extended from the sides of the engine's chassis. A keying
location point is provided on the bottom of the engine to assist with alignment.
When securing the engine with self-tapping screws, Metrologic recommends:
using M2.2 x 4.5 Philips Pan Head, Type AB, Steel, Zinc Clear, Trivalent
self-tapping screws
not exceeding 1.75 +0.5 in-lb [2.02 +6 cm-kg] of torque
a minimum mount thickness of 0.3 mm
Figure 7. IS4910-01 Dimensions