  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
9
MOUNTING SPECIFICATIONS
IS4910-00 Dimensions
The IS4910-00 model has two blind holes located on the bottom of the engine.
These bind holes are provided for applications that require mounting with
self-tapping screws. A keying location point is also provided on the bottom of the
engine to assist with alignment.
When securing the engine with self-tapping screws, Metrologic recommends:
using M2.2 x 4.5 Philips Pan Head, Type AB, Steel, Zinc Clear, Trivalent
self-tapping screws
not exceeding 1.75 +0.5 in-lb [2.02 +6 cm-kg] of torque
a minimum mount thickness of 0.3 mm
Figure 6. IS4910-00 Dimensions
Specifications are subject to change without notice.