OBJECT DETECTION DEVICE
Figure 4. Object Detection Field
Please note certain ambient light conditions may interfere with the object
detection mechanism, resulting in false activation of the scanner. To mitigate the
problem, please try one of the following suggestions:
1. Avoid mounting the scanner directly facing the ambient light source.
2. Avoid mounting the scanner facing a light-colored or reflective surface.
3. Avoid mounting the scanner towards a surface at a distance close to the
long range (9" – 11") of object detection
4. Configure the object detection range to short (4" – 7").