Strona 1 - METROLOGIC INSTRUMENTS, INC

METROLOGIC INSTRUMENTS, INC.MS7100 Series Fixed Projection Laser ScannerInstallation and User’s GuideMLPN 2408Printed in USAOctober 1998

Strona 2 - Locations:

6Scanner Installation: Powered by Host DeviceThe MS7100 scanner interfaces terminate to a 10-pin modular jack. Connectthe 10-pin modular plug of the

Strona 3 - Table of Contents

7Scanner Installation to the PC for the Scanner with Built-inPC Keyboard Wedge Interface To maintain compliance with applicable standards, all circuit

Strona 4

8Green and Red LEDs: When the red LED is on, thisindicates that the laser is on. When the green LED flashes on,the scanner has read a bar code success

Strona 5 - Introduction

9Audible Indicators When the MS7100 scanner is in operation, it provides audible feedback.These sounds indicate the status of t

Strona 6 - Scanner and Accessories

10Failure Modes Flashing Red and One Razzberry ToneThis indicates the scanner has experienced a laser subsystem failure. Retur

Strona 7 - Quick Start

11Visual Indicators There are a red LED and a green LED on the head of the Orbit MS7100.When the sc

Strona 8 - Operational Test

12LabelsEach scanner has labels on the bottom of the unit. One label containsinformation such as the model number, date of manufacture, serial number

Strona 9

13Depth of Field Specifications (based on 100% UPC bar codes)Optimal Depth of Field (default) Close Depth of Field

Strona 10

14Normal Depth of FieldFar Depth of Field

Strona 11 - PC Keyboard Wedge Interface

15Depth of Field by Minimum Bar Code Element WidthOptimal Depth of Field (default)

Strona 12 - ú

iiLocations:USA Corporate Headquarters EuropeMetrologic Instruments, Inc. Metrologic Instruments GmbH90 Coles Road Dornierstrasse 2Blackwood, NJ 0801

Strona 14 - Failure Modes

17Normal Depth of Field

Strona 15

18Far Depth of Field

Strona 16

19MaintenanceSmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning. 1. Spra

Strona 17 - (based on 100% UPC bar codes)

20Troubleshooting GuideThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Strona 18 - Far Depth of Field

21SYMPTOMThe unit powers up properly, lasers come on, but the unit does not scan and does notbeep when a bar code is presentedPOSSIBLE CAUSE(S) SOLUT

Strona 19

22SYMPTOMScanner beeps at some bar codes and NOT for others of the same bar code symbologyPOSSIBLE CAUSE(S) SOLUTIONThe print quality of the bar code

Strona 20 - Close Depth of Field

23Keyboard Wedge OnlySYMPTOMThe unit scans the bar code but there is no dataPOSSIBLE CAUSE(S) SOLUTIONConfiguration is not correct Make sure the scann

Strona 21

24RS-232 onlySYMPTOMPower-up OK and scans OK but does not communicate properly to the hostPOSSIBLE CAUSE(S) SOLUTIONCom port at the host is not workin

Strona 22

25RS-232 Demonstration ProgramIf an RS-232 scanner is not communicating with your IBM compatible PC, key in thefollowing BASIC program to test that

Strona 23 - Maintenance

iiiTable of ContentsIntroduction ... 1Scanner and Accessories ...

Strona 24 - Troubleshooting Guide

26Applications and ProtocolsThe model number on each scanner includes the scanner number andcommunications protocol.Scanner Version Identifier Communi

Strona 25

27Appendix ADesign SpecificationsOperationalLight Source: VLD 675 ± 5nm, 0.681 milliwatts (PEAK)Depth of Field: 0 mm to 215 mm (0" to 8.5"

Strona 26

28ElectricalInput Voltage: 5.2VDC ± 0.25VPower : 1.1 WOperating Current : 225 mADC Transformers: Class II; 5.2 V @650 mA Laser Class: CDRH: Class IIa

Strona 27

29Appendix BDefault SettingsMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the

Strona 28

30Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXDTS/NIXDORF * TTNCR F TTNCR S TTPoll Light Pen Source TTBeeper Tone Normal TT TT TT TT TTBeep/T

Strona 29

31Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXTransmit Codabar TT TT TT TTStart/Stop CharactersCLSI Editing (Enable) TT TT TT TTTransmit Mod

Strona 30 - Applications and Protocols

32Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXTwo Digit Supplements TT TT as code TT TT39Five Digit Supplements TT TT as code TT TT39Bookland

Strona 31 - Appendix A

33Appendix CPin AssignmentsPin Assignments for the PowerLink CableThe MS7100 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin

Strona 32

34Pin Assignments for the PowerLink Cable Keyboard WedgeInterface The MS7100 Keyboard Wedge scanner interface terminates to a 10-pinmodular jack. Conn

Strona 33 - Appendix B

35 Adapter Cable Connectors 5-pin Male 6-pin Female PowerLink Cable Connectors 5-pin Female 6-pin Male Pin A

Strona 34 - 232* Pen 46XX

ivAppendix ADesign Specifications 27, 28Appendix BDefault Settings 29-32Appendix CPin Assignments 33-35Appendix DWarranty and Disclaimer 36, 37Appendi

Strona 35

36Appendix DWarranty and DisclaimerLimited WarrantyProducts manufactured by Metrologic have a 2-year limited warranty fromdate of manufacture.This war

Strona 36

37DisclaimerMetrologic Instruments, Inc. and the author or authors make no claims or warranties with respectto the contents or accuracy of this public

Strona 37 - Appendix C

38Appendix ENoticesNoticeThis equipment has been tested and found to comply with limits for a Class A digital device,pursuant to Part 15 of the FCC Ru

Strona 38

39AnmerkungNach Überprüfung dieses Geräts wurde festgestellt, daß es den Grenzwerten für Digitalgeräte derKlasse A gemäß Teil 15 der Richtlinien der U

Strona 39 - Adapter Cable Connectors

40IndexAAccessories 2AC input/outlet 2, 4, 5, 7Adaptercable 2, 7, 35Approvals 12Assignmentspin 33-35Audible indicators 9Authorized service center 36Au

Strona 40 - Appendix D

41Light Pen 1, 2, 4, 6, 26, RDATA 3333 Recommendation 7Light source 27 Red led 3-6, 8, 9, 11, 20List 2 Repair 10, 36M property 36Maintenance 19Manuf

Strona 41

1IntroductionOrbit™ is an aggressive, omnidirectional laser bar code scanner. Light-weightand rugged, Orbit is small in size, but BIG in performance.

Strona 42 - Appendix E

2Scanner and AccessoriesThe following is a list of the parts included in the MS7100 kit.! MS7100 Hand-Held Laser Scanner - Refer to page 26 for availa

Strona 43

3Quick Start 1.) Plug in the scanner. When the MS7100 is ready to scan, the red LED will turn on, then the green LED will flash and the scan

Strona 44

4Operational TestMetrologic recommends using the external power supply provided with thescanner when operating the MS7100. When using power supplied b

Strona 45

5Scanner Installation: Powered by External Power SupplyTo maintain compliance with applicable standards, all circuits connected to thescanner must me

Komentarze do niniejszej Instrukcji

Brak uwag